The new 6.2 version of Planmeca PlanCAD® Easy introduces major awaited improvements and exciting new features. With the new version, the scanning process and producing high-quality scans is even easier than before. The new features include the possibility to do 360-degree scans, enabling for example the scanning of dentures.
Improvements in model generation include improved model bottom generation and gap fill. These improvements also improve the accuracy of the scans.
The generation of the bottom of the scanned models has been considerably improved in the new software version. As a result, extra material is no longer added to the model bottom when the model is generated.
New PlanCAD Easy 6.2
No extra material added
Previous PlanCAD Easy versions
Extra material added to the model
The reconstruction of the interproximal surfaces has been improved remarkably. See the difference between the new and the previous software versions in the pictures below.
New PlanCAD Easy 6.2
The improved gap fill shows the space between teeth
Previous PlanCAD Easy versions
Gaps between the teeth are filled
Interim model is the model that displays during and after scanning but before the model has been generated. The new version brings a couple of changes to the interim model.
Islands of redundant data previously shown in dark blue on the interim model are now removed as soon as you stop scanning, creating a cleaner interim model. Previously, the data which was unconnected to the model (shown in dark blue in the picture) was not erased until the model was generated.
New PlanCAD Easy 6.2
Previous PlanCAD Easy versions
With the new software version, extra data is automatically removed from the interim model
New PlanCAD Easy 6.2
Extra data is automatically removed for a cleaner interim model
Previous PlanCAD Easy versions
Areas with extra data appear dark, confusing users
You can now also scan the underside of an appliance, such as dentures. See the examples below of one denture model.
Open Bite is now an option on the Setup tab. The option is used for scanning for dental appliances that require a gap between the upper and lower jaw, such as night guards.
The colour model is now displayed by default instead of the stone model.
The Active Delete function has been improved. The Scan Settings now has an option for the Active Delete function to be turned on by default, if preferred.
To sharpen the details of the model, move the Resolution slider in the Scan Settings to the right from A to E. Please note that the duration of model generation can increase dramatically when using the higher resolutions (D & E).
A dialog box will appear if a Windows update is being installed in the background. Scanning is not recommended during Windows updates.